T100e thermostatic care & care plus
23
7 Water continues
to flow when unit is
isolated at isolating
switch.
8 Pressure relief device
has operated (water
ejected from PRD
tube).
6.4 Blocked
connecting tube to
pressure switch.
7.1 Debris in solenoid.
8.1 Blocked
showerhead.
8.2 Twisted/blocked
flexible shower hose.
8.3 Showerhead
not removed whilst
commissioning.
6.4.1 Make sure the tube from solenoid valve to
pressure switch is not kinked or blocked.
7.1.1 Contact Customer Service for advice.
8.1.1 Clean or replace blocked showerhead
cartridge and then fit a new PRD.
8.2.1 Check for free passage through hose.
Replace the hose if necessary, then fit new PRD.
8.3.1 Fit new PRD. Commission unit with
showerhead removed.
FAULT FINDING
Problem/Symptom Cause Action/Cure
Y-001-A
In the unlikely event of unit failure other than detailed in the fault finding page,
please contact Customer Service for advice.
N-003-A
Note: Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.