Page #9 background imageLoading...
Page #9 background image
34020-01385 · 00 · 07/2022
9EN
Menu controlTruma CP plus
When a new command is entered via the Truma App,
the connected appliances and the Truma CPplus are
activated with the specified values�
When a new or replacement Truma iNet Box is con-
nected to the bus system, repeat the procedure de-
scribed in “Initial start-up” (page12)� Then activate
the app mode, see “6�4 App mode with iNet Box” on
page13�
The time switch is disabled in appmode�
5 Menu control
hot
eco
2
1
3
8
4
5
6
7
9
1 Display
2 Status bar
3 Menu bar (top)
4 Menu bar (bottom)
5 230 V power supply indicator (mains electricity)
6 Time switch indicator
7 Settings / values ("displayed text”)
8 Rotary push button
9 Back button

Other manuals for Truma CP plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma CP plus and is the answer not in the manual?

Truma CP plus Specifications

General IconGeneral
DisplayLCD
Power supply12 V DC
Quiescent current consumption (at 12 V)Approx. 5 mA
Temperature range-15 °C to +60 °C
Protection classIP20
CompatibilityTruma Combi heaters