20
34020-01385 · 00 · 07/2022
EN
Operation Truma CP plus
Enter the start time
Set the hours then the minutes with the rotary push
button�
In 12h mode: A: am, P: pm�
Enter the end time
Set the hours then the minutes with the rotary push
button�
If the start/end point was exceeded during entry, the
operating parameters will not apply until the next
start/end point is reached� Until then, the operating
parameters that have been set outside the time
switch remain valid�
After this, you can set the following menu items
that are within the switching interval:
Setting the room temperature
Setting the hot water level
Selecting the energy type
Selecting the fan level
Activating the time switch (ON)
Deactivating the time switch (OFF)
Switching lighting on / off
Setting the time
6.12 Service menu
Use the rotary push button to select in the menu
line�
Press the rotary push button to go to the setting
level�
Choose the desired setting with the rotary push
button�
Press the rotary push button to confirm the value�
Calibrating the room temperature sensor of the
heater (OFFSET)
The room temperature sensor of the heater can be in-
dividually adjusted to the sensor’s installation situation�
The setting can be made in increments of 0�5°C from
0°C to -5°C�
Example:
Set room temperature 23°C;
OFFSET = -1°C;
Setpoint for heater = 22°C
Default setting: 0°C (Celsius)�
AC SET
1,2
The sensed room temperature can – during operation of
the automatic climate control – be perceived differently
during cooling than during heating� "AC SET" is used

Other manuals for Truma CP plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma CP plus and is the answer not in the manual?

Truma CP plus Specifications

General IconGeneral
DisplayLCD
Power supply12 V DC
Quiescent current consumption (at 12 V)Approx. 5 mA
Temperature range-15 °C to +60 °C
Protection classIP20
CompatibilityTruma Combi heaters

Related product manuals