Saphir Maintenance
17EN
40090-00130 · 01 · 11/2023

Then remove air filter from the front.

Reassemble the cleaned or changed air filter
(Fig. 24-1). Make sure that the air filter is correct-
ly aligned, as indicated by the arrow printed on it
(Fig. 24-3).

Re-fit the Saphir US lamellar insert (Fig. 24-1), clip
and sensor in the same position during assembly.

Re-fit the cold air ducts.
1
3
2
Fig. 24
NOTICE
Operating the device without a filter can
cause evaporator coil soiling, which can
have a detrimental eect on the perfor-
mance of the device!

When installing the air filter, the printed
arrows (Fig. 24-3) must point towards the
device – they indicate the circulated air flow
direction.

Never operate the device without a filter.
8.2 Insert/change batteries
The battery cover is on the rear of the remote control
(Fig. 25).

When removing the batteries, pairing between the
remote control and the air conditioning system is
maintained. The time and timer are not maintained.

Only use leakproof micro-batteries, type LR 3, AM4,
AAA, MN 2400 (1.5 V).

Observe the positive/negative positions when insert-
ing new batteries.

Then set the time and timer again.
Fig. 25
Low used batteries can leak and damage the remote
control.

Remove batteries when the remote control will not
be used for longer periods.