Saphir Disposal and Recycling
19EN
40090-00130 · 01 · 11/2023
11 Disposal and Recycling
The air conditioning system must be disposed of only
by experts in accordance with the administrative reg-
ulations of the respective country in which it is used.
National regulations and laws must be observed.
USA:
Clean Air Act, 42 U.S. Code § 7671g, 40 CFR Part 82
Subpart F
Canada:
Environmental Code of Practice for the Elimination of
Fluorocarbon Emissions from Refrigeration and Air Con-
ditioning Systems.
The remote control and the batteries must not be
disposed of in domestic waste, but rather must be
recycled separately via a collection point. You then also
make your contribution to reuse and recycling.
12 Technical Data
Established in line with AHRI Standard 210/240.
Designation Saphir
Cooling capacity
equivalent
7000 BTU / h
Heating capacity
equivalent
6500 BTU / h
Electrical rating 120 VAC, 60 Hz ± 5%
single phase
Compressor
Rated Load
6.5 A
Compressor
Locked Rotor
38 A
Fan Motor
Rated Load
1.1 / 1.16 A
(indoor / outdoor)
Fan Motor
Locked Rotor
0,18 / 019 HP
(indoor / outdoor)
Refrigerant R-410A
16.9 oz (480 g)
Minimum wire
Size copper
3 x AWG 12 / 3 x 3.3 mm
AC Circuit protection
installer supplied
20 Amp
Limits of use 39 – 113°F
(4°C – 45°C)
Max air conditioner
incline in operation
8% (4.5°)
Weight, plus
installation material
54.5 lbs (24.7 kg)
Adjustable tempera-
ture range
62 - 88°F
16 - 31°C
Protection type IPX5
Generator size
3
1
For wire length over 24 ft., consult the National Electrical Code for
proper sizing.
Circuit Protection: Time delay fuse or circuit breaker required.
3
See “Operation with generator or power inverter“ on page 12
An interior air sensor prevents the compressor from op-
erating at temperatures of less than 61 °F (16 °C) during
cooling.
An anti-freeze sensor prevents non-permitted ice forma-
tion on the evaporator coil.
A temperature switch prevents excessive current and
temperature at the compressor.
Truma Gerätetechnik reserves the right to make
technical changes!