Specifications A-3
Table A-3
Electrostatic Classifier Specifications
Mode of operation
Bipolar diffusion charge neutralization and differential mobility analysis (requires
installation of DMA).
Flow rates
Sheath flow .....................................
2 to 30 L/min ±2% of reading
Aerosol flow ....................................
When measured with inlet impactor:
0.2 to 0.8 L/min with 0.0457 cm nozzle
0.3 to 1.0 L/min with 0.0508 cm nozzle
0.6 to 2.1 L/min with 0.0710 cm nozzle
Otherwise: determined by external pressure
or vacuum.
DMA Voltage
10 to 10,000 VDC ± 0.5% over full range.
Negative polarity (standard) or switchable negative and positive polarity (optional)
*TSI is authorized by the United
States Nuclear Regulatory
Commission to distribute these
Aerosol Neutralizers. If your
location is within the United States,
no other federal license is required.
Check local regulations for your
own protection. Neutralizers are
shipped separately from other
system components. End-user
name and address is required.
Charger/Neutralizer
Aerosol Neutralizer Model 3077 ......
Bipolar, Kr-85, 74 MBq (2 mCi), half-life of
10.7 years, lead shielding available
Aerosol Neutralizer Model 3077A ...
Bipolar, Kr-85, 370 MBq (10 mCi), half-life
of 10.7 years, lead shielding available
Advanced Aerosol Neutralizer
Model 3088 .....................................
Bipolar, soft x-ray, E < 9.5 keV, x-ray
source life before exchange 8760 operating
hours
Aerosol temperature range
10 to 40°C
Aerosol pressure range
70 to 125 kPa [0.70 to 1.25 atm)
Aerosol temperature range
10 to 40°C
Aerosol pressure range
70 to 125 kPa [0.70 to 1.25 atm)
Front panel display
5.7 in VGA color touchscreen with Windows
®
CE
Calibration
ISO 15900 compliant
NIST-traceable voltage and flow standards
Dimensions (LWH)
40.5 cm 28 cm 40.5 cm (16 in 11 in 16 in)
Weight
14.5 kg (32 lb)
Ports
Aerosol Inlet ....................................
Polydisperse Flow ...........................
Sheath Flow + .................................
Sheath Flow - ..................................
¼-in. OD
¼-in. OD
3
8-in. OD
3
8-in. OD
Power requirements
100 to 240 VAC, 50 to 60 Hz, 200 W maximum

Table of Contents

Other manuals for TSI Instruments 3082

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSI Instruments 3082 and is the answer not in the manual?

TSI Instruments 3082 Specifications

General IconGeneral
BrandTSI Instruments
Model3082
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals