6. SPECIFICATION OF INPUTS AND OUTPUTS
6.3.3 Power on/off sequence
The device boots if:
Terminal 15 is powered (typically BAT+), or
Wake-up input is powered (typically BAT+)
Once the device has started, the application software is responsible for saving all data to flash memory
before it powers down the device. This is necessary to ensure data integrity.
6.3.4 Maximum ratings
Symbol Parameter Min Max Unit
V
in
Permanent (DC) input voltage -33 33 V
V
in
Transient peak input voltage 500 ms -50 50 V
V
in
Transient peak input voltage 1 ms -200 200 V
6.3.5 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
R
pd
Pull-down resistor to GND 10 12 kΩ
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
τ
in
Input low-pass filter 0.1 0.3 ms
6.4 External Wake-up
6.4.1 Pinout
Connector Pin no. Function
C1 10 External Wake-up
6.4.2 Functional description
External Wake-up provides the possibility to wake up the Vision 307 device from the Suspend mode or
Power-off mode by an external event (see figure 10).
6.4.3 Maximum ratings
Symbol Parameter Min Max Unit
V
in
Permanent (DC) input voltage -33 33 V
V
in
Transient peak input voltage 500 ms -50 50 V