6. SPECIFICATION OF INPUTS AND OUTPUTS
6.4.4 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
R
pd
Pull-down resistor to GND 100 120 kΩ
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
τ
in
Input low-pass filter 0.1 0.3 ms
6.5 Service Enable
6.5.1 Pinout
Connector Pin no. Function
C1 27 Service Enable
6.5.2 Functional description
Service Enable is used for debugging and servicing functionalities. For further information, see [5, 6].
6.5.3 Maximum ratings
Symbol Parameter Min Max Unit
V
in max
Permanent (DC) input voltage -1 33 V
6.5.4 Characteristics
Symbol Parameter Min Max Unit
C
in
Pin input capacitance 8 12 nF
V
IL
Input voltage for low level -1 2 V
V
IH
Input voltage for high level 3 32 V
© TTControl GmbH 2024. All rights reserved.