38
Configuration of the Absence Period, Absence Start, Absence Stop, Not in Bed, Not
Out of Bed and enable/disable Daylight savings is done via the
“Advanced Mode”.
Suggested Configuration: this can be changed using “Advanced Mode”.
Contact Type NC
Input Channel 1
Cable Connection RJ11
Pad Type Bed or Chair (depending on application)
Set times Absence Period – How long the client is out of bed
before an alarm is triggered.
Absence Start – The time at which monitoring should
start
Absence Stop – The time at which monitoring should
end
Not in Bed - the time when a client should be in bed
Not Out Bed - the time when a client should be out of
bed
Daylight Saving - On
Monitoring Deactivated Monitoring can be disabled for 60 mins
The Universal Sensor can now be connected to a Bed Pad with a normally closed
relay (sold separately) and to the Tunstall Home unit. Tunstall recommends
completing a test call before leaving the property.
Note: to
Note: to Note: to
Note: to enable
enableenable
enable
24
2424
24-
--
-hour
hourhour
hour
continuous
continuouscontinuous
continuous
monitoring
monitoring monitoring
monitoring program the Absence Start and
program the Absence Start and program the Absence Start and
program the Absence Start and
Absence Stop times to be the same.
Absence Stop times to be the same. Absence Stop times to be the same.
Absence Stop times to be the same.
E.g.
E.g. E.g.
E.g. Absence Start: 00:00, Absence Stop: 00:00
Note: whilst operating in
Note: whilst operating in Note: whilst operating in
Note: whilst operating in 24
2424
24-
--
-hour
hourhour
hour
continuo
continuocontinuo
continuou
uu
us
ss
s
monitoring
monitoringmonitoring
monitoring,
,,
,
th
thth
the Universal Sensor
e Universal Sensor e Universal Sensor
e Universal Sensor
will raise an alarm
will raise an alarm will raise an alarm
will raise an alarm only
only only
only once per absence period
once per absence periodonce per absence period
once per absence period
(if the absence persists)
(if the absence persists)(if the absence persists)
(if the absence persists).
. .
. I
II
If
f f
f
operating in
operating inoperating in
operating in
non
nonnon
non-
--
-24
2424
24-
--
-hour
hourhour
hour
monitoring
monitoringmonitoring
monitoring,
, ,
, the Universal Sensor shall raise an alarm
the Universal Sensor shall raise an alarm the Universal Sensor shall raise an alarm
the Universal Sensor shall raise an alarm
everytime the absence period is reached
everytime the absence period is reachedeverytime the absence period is reached
everytime the absence period is reached
(if absence persists)
(if absence persists)(if absence persists)
(if absence persists).
. .
. For example, if
For example, if For example, if
For example, if
the absence period is set to 10 minutes, an alarm will be raised every 10
the absence period is set to 10 minutes, an alarm will be raised every 10 the absence period is set to 10 minutes, an alarm will be raised every 10
the absence period is set to 10 minutes, an alarm will be raised every 10
minutes until the user returns to bed.
minutes until the user returns to bed. minutes until the user returns to bed.
minutes until the user returns to bed.