EasyManuals Logo

TurboChef i5 Service Manual

TurboChef i5
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
40 TROUBLESHOOTING
Troubleshooting:
F2: LOW TMP (Cook Temperature Low)
YES
Replace the defective
heater. (page A-11)
Replace the solid state
relay. (page A-5)
NO
YES
YES
Replace the I/O
control board (page
A-8).
Correct wiring.
YES
NO
Reset and determine
why it tripped – excess
grease buildup, etc.
(Figure 31, page 34)
Is either of the heater ele-
ments defective? (heaters
should have a resistance of
14.4 Ohms)
Is the high-limit
thermostat tripped?
Is the solid state relay
defective?
Is wiring from the
solid state relay to the
I/O control board OK?
(See page 51 for
schematic)
Is the RTD
functioning properly?
Ensure wiring is
correct. If necessary,
replace RTD. (page
A-11)
NO
NO
YES
NO