Commissioning
Commissioning the device in EtherNet/IP
86
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
Basic Class (VSC 180)
Attr. no. Designation Get/set Type Meaning
Dec. Hex.
1 0x01 IOL 0 - Manual output reset after
overcurrent
G/S USINT 0 = no
1 = yes
2 0x02 IOL 1 - Manual output reset after
overcurrent
G/S USINT 0 = no
1 = yes
3 0x03 IOL 2 - Manual output reset after
overcurrent
G/S USINT 0 = no
1 = yes
4 0x04 IOL 3 - Manual output reset after
overcurrent
G/S USINT 0 = no
1 = yes
5 0x05 Overcurrent supply VAUX1 K0 G/S USINT 0 = no
1 = yes
6 0x06 Overcurrent supply VAUX1 K1 G/S USINT 0 = no
1 = yes
7 0x07 Overcurrent supply VAUX1 K2 G/S USINT 0 = no
1 = yes
8 0x08 Overcurrent supply VAUX1 K3 G/S USINT 0 = no
1 = yes
9 0x09 IOL 0 – Overcurrent output G USINT 0 = inactive
1 = active
10 0x0A IOL 1 – Overcurrent output G USINT 0 = inactive
1 = active
11 0x0B IOL 2 – Overcurrent output G USINT 0 = inactive
1 = active
12 0x0C IOL 3 – Overcurrent output G USINT 0 = inactive
1 = active
13 0x0D IOL 0 – DI input G USINT 01
14 0x0E IOL 1 – DI input G USINT 01
15 0x0F IOL 2 –DI input G USINT 01
16 0x10 IOL 3 – DI input G USINT 01
17 0x11 IOL0 - Input value valid (Data Valid
Signal)
G USINT 0 = no
1 = yes
18 0x12 IOL0 - Input value valid (Data Valid
Signal)
G USINT 0 = no
1 = yes
19 0x13 IOL4 - Input value valid (Data Valid
Signal)
G USINT 0 = no
1 = yes
20 0x14 IOL6 - Input value valid (Data Valid
Signal)
G USINT 0 = no
1 = yes
21 0x15 Output value G Byte 0 = IOL 0
1 = IOL 1
2 = IOL 2
3 = IOL 3