OPERATION
&
MAINTENANCE
MANUAL
Electronic Tabletop Autoclaves
Models 1730, 2340, 2540, 3140, 3850, 3870
E, EK, EA & EKA

Other manuals for Tuttnauer 3850EA

Questions and Answers

  • T
    Tracy LoweAug 25, 2025
    What does ‘Low Heat’ mean on my Tuttnauer 3850EA?
    • A
      Anthony ClarkAug 26, 2025
      If the message ‘Low Heat’ is displayed during heat up on your Tuttnauer Laboratory Equipment, it indicates a bad temperature sensor. If heating elements are remaining on instead of cycling on and off, call for a technician.
  • C
    Curtis PierceAug 26, 2025
    How to clean a very dirty chamber in my Tuttnauer 3850EA Laboratory Equipment?
    • J
      John BautistaAug 27, 2025
      If the chamber of your Tuttnauer Laboratory Equipment is very dirty, use Chamber Brite ™ to clean the autoclave; very dirty machines may require two cleanings.
  • J
    Julie Moore MDAug 27, 2025
    What to do if Tuttnauer Laboratory Equipment process fails during heating stage with a HIGH TEMP message?
    • B
      Betty JacksonAug 27, 2025
      If your Tuttnauer Laboratory Equipment process fails while initiating the heating stage and displays a HIGH TEMP message, try changing the setting of the thermostat.
  • G
    garciaericAug 27, 2025
    How to troubleshoot Tuttnauer Laboratory Equipment machine not responding?
    • O
      ojohnsonAug 28, 2025
      If your Tuttnauer Laboratory Equipment machine isn't responding, verify that the main switch is in the ‘On’ position, the power cord is properly connected to both the machine and the mains, and the circuit breaker hasn't tripped. Also, check the reset button on the cut-out thermostat.
  • E
    Ethan CastroAug 28, 2025
    What should I do if my Tuttnauer Laboratory Equipment shows ‘Low Pres’?
    • A
      April HeathAug 28, 2025
      If the 'Low Pres' message is displayed on your Tuttnauer Laboratory Equipment, clean the water level electrode inside the vessel. Also, ensure the door is fully closed, the door gasket is properly seated, and there is no steam leakage. Check the leveling of the machine.
  • M
    michaelhayesAug 29, 2025
    How to fix ‘High Pres’ error on Tuttnauer Laboratory Equipment?
    • H
      henrykellyAug 29, 2025
      If the 'High Pres' message appears on your Tuttnauer Laboratory Equipment, the air jet might be clogged; clean it. It could also mean that the heating elements are continuously on, or the temperature sensor is faulty. In these cases, contact a technician.
  • M
    michelleschroederAug 30, 2025
    How to unclog the drain on Tuttnauer 3850EA?
    • E
      Elijah SmithAug 30, 2025
      If the drain of your Tuttnauer Laboratory Equipment is clogged: 1. Open the drain by turning it counterclockwise and place a heavy object over the reservoir cover. 2. Blow compressed air into the drain to force debris back into the reservoir, then clean out the reservoir. 3. Alternatively, disassemble the drain valve, clean it, and blow out the line. Reassemble the valve, ensuring the large 'O' ring is properly seated.
  • J
    Jennifer GuerreroAug 23, 2025
    What should I do if my Tuttnauer 3850EA displays ‘High Pres’?
    • C
      Clinton JohnsonAug 23, 2025
      If your Tuttnauer Laboratory Equipment displays ‘High Pres’, clean the air jet. Ensure the sterilization time and temperature are set correctly; if unsure, use the default settings. Also, make sure the autoclave is not too heavily loaded.
  • A
    anthony83Sep 1, 2025
    What to do if my Tuttnauer Laboratory Equipment is not responding?
    • B
      Brandon HarperSep 1, 2025
      If your Tuttnauer Laboratory Equipment is not responding, ensure the main switch is in the ‘On’ position. Also, verify the power cord is properly connected to both the machine and the mains. Check the reset button on the cut-out thermostat and make sure the circuit breaker hasn't tripped; lift the circuit breaker lever if it has.
  • J
    Jose HoustonSep 2, 2025
    Why is my Tuttnauer Laboratory Equipment leaking at the door?
    • J
      Jeremy JacksonSep 2, 2025
      If your Tuttnauer Laboratory Equipment is leaking at the door, ensure the door is tightened enough and the door gasket is sealing the chamber. If necessary, replace the door gasket.

Summary

GENERAL

Incoming Inspection

Inspect the autoclave upon arrival for any signs of damage.

Warranty

Details the instrument's warranty coverage for defects in material and workmanship.

TECHNICAL DATA

Water Quality

Specifies the physical characteristics and acceptable contaminant levels for water used.

KEYBOARD (Keys and Display)

Description and Functions of the Control Panel Keyboard

Details the program keys and other operational keys on the control panel.

Displayed Messages and Safety Measures

Lists and explains various error messages and safety precautions.

STERILIZATION PROGRAMS

INSTALLATION INSTRUCTIONS

Electrical

Covers electrical connection requirements, safety relays, and compliance with regulations.

PREPARATION BEFORE STERILIZATION

Sterilization Load Setup and Indicators

Covers placement of indicators, spore tests, and proper load arrangement.

OPERATING INSTRUCTIONS

Initial Setup and Operation Start

Guides on initial setup, filling reservoir, and starting the autoclave.

MAINTENANCE INSTRUCTIONS

Preventive and Scheduled Maintenance

Outlines routine maintenance tasks for daily, weekly, and periodic intervals.

Cleaning the Air Jet

Explains the importance and procedure for cleaning the air jet to prevent failures.

Cleaning with Chamber Brite

Details the procedure for cleaning the autoclave using Chamber Brite cleaner.

TROUBLESHOOTING FOR THE OPERATOR

Machine Not Responding & Low Heat

Provides solutions for the machine not responding and 'Low Heat' errors.

Low Water, Low Pressure & Low Temperature Issues

Offers solutions for 'Low Water', 'Low Pres', and 'Low Temp' error messages.

High Temperature, Printer & Door Leaks

Addresses 'High Temp' errors, printer issues, and door leaks.

Long Cycle Times & Clogged Components

Solves issues like long heat-up, long exhaust, and clogged strainers.

Tuttnauer 3850EA Specifications

General IconGeneral
Voltage230V
Frequency50/60 Hz
TypeAutoclave
Chamber Volume85 liters
MaterialStainless steel
Cycle TimeVaries depending on cycle parameters