Tuttnauer 5075 - Service Manual

Tuttnauer 5075
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATION
&
MAINTENANCE
MANUAL
Laboratory Vertical Steam Sterilizers
models 5050, 5075
ELV-D
Standard Autoclave
ELVC-D
Including Fast Cooling System
Cat. No. MAN205-0451001EN Rev B
Tuttnauer Europe b.v., Paardeweide 36, 4824 EH, Breda, P.O. Box 7191, 4800 GD Breda, Netherlands. +31/76-5423510,
Fax: +31/76-5423540
Tuttnauer U.S.A. Co, Ltd. 25 Power Drive Hauppauge, NY, 11788, USA. Tel (631) 737 4850, (800) 624 5836,
Fax: (631) 737 0720

Table of Contents

Other manuals for Tuttnauer 5075

Questions and Answers

  • C
    chelsea88Sep 10, 2025
    What causes the safety relief valve on my Tuttnauer Laboratory Equipment to open at a lower pressure than specified?
    • M
      Michael PittmanSep 10, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment opens at a pressure lower than specified, it could be clogged or faulty. Replace the relief valve and check the water quality to resolve this.
  • J
    jparkerSep 10, 2025
    Why does the safety relief valve on my Tuttnauer 5075 Laboratory Equipment open at a pressure higher than specified?
    • R
      Robert CarsonSep 10, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment opens at a pressure higher (more than 10%) than specified, the relief valve is likely faulty and needs replacement.
  • T
    Timothy KellySep 12, 2025
    Why doesn't the safety relief valve on my Tuttnauer Laboratory Equipment close in time?
    • J
      Julie RichardsSep 12, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment does not close in time (2-3 seconds), the valve is likely faulty and needs replacement.
  • K
    Kristin BradySep 12, 2025
    What does 'High Temp' mean on my Tuttnauer Steriliser, and how do I resolve it?
    • J
      Jennifer TravisSep 12, 2025
      If the Tuttnauer Steriliser displays 'High Temp', it means the temperature rose 7°F (4°C) above the sterilization temperature during the sterilization stage for 2 seconds. You should perform a new cycle.
  • S
    Susan EvansSep 12, 2025
    Why is the safety relief valve on my Tuttnauer 5075 Laboratory Equipment constantly leaking?
    • J
      johnsonnicholasSep 12, 2025
      If the safety relief valve on your Tuttnauer Laboratory Equipment leaks constantly, the valve is likely faulty and needs replacement. Additionally, check the water quality.
  • D
    David PageSep 12, 2025
    What to do if 'Low Vacuum' is displayed on my Tuttnauer Steriliser?
    • J
      Justin BakerSep 12, 2025
      If the Tuttnauer Steriliser displays 'Low Vacuum,' it means that the vacuum level of 15kPa was not reached within 20 minutes after the cycle started. You can try performing a new cycle. If the issue continues, it may require technical assistance. Also, the bio-hazard filter may be clogged and require technical service.
  • S
    Susan GreeneSep 12, 2025
    What does 'High Temp. (Ending)' mean on my Tuttnauer Steriliser and how can I fix it?
    • R
      Russell SmithSep 12, 2025
      If the Tuttnauer Steriliser displays 'High Temp. (Ending)', it means the system cannot reach the required temperature in the chamber within 10 minutes since exhaust. You should perform a new cycle.
  • F
    foxstevenSep 12, 2025
    What does 'Heat Time Error' mean on my Tuttnauer Steriliser, and how do I fix it?
    • R
      Richard SmithSep 12, 2025
      If the Tuttnauer Steriliser displays 'Heat Time Error', it means the system couldn't reach the required temperature in the chamber within the preset time. Make sure that the autoclave is not overloaded.
  • F
    fbarnettSep 12, 2025
    What causes a 'No Water' error on my Tuttnauer Steriliser and how can I resolve it?
    • M
      Melissa HorneSep 12, 2025
      If the Tuttnauer Steriliser displays 'No Water', it means the electrode in the chamber didn't sense water within the preset time. First, check and fix the mineral-free water supply. Then, check and clean the water inlet filter. Finally, clean the water level electrode.
  • E
    elizabethstewartSep 12, 2025
    How to fix 'High Temp. (Cooling)' error on Tuttnauer Steriliser?
    • C
      Courtney BradfordSep 12, 2025
      If the Tuttnauer Steriliser displays 'High Temp. (Cooling)', this indicates that the system cannot reach the sterilization temperature during the cooling stage within the preset time. Check and fix the city (tap) water supply.

Summary

OPERATION & MAINTENANCE MANUAL

Laboratory Vertical Steam Sterilizers 5050, 5075

Details the 5050 and 5075 vertical steam sterilizers.

1. GENERAL

Incoming Inspection and Warranty

Covers initial inspection of the unit and warranty terms.

2. SAFETY INSTRUCTIONS

General Safety Guidelines

Crucial safety precautions for autoclave operation, maintenance, and usage.

3. TECHNICAL DATA

Introduction and Overview

Introduces models and their purpose.

Operating Conditions and Standards

Specifies environmental, operational limits, and compliance standards.

Specifications and Electrical Data

Details technical specifications, dimensions, and electrical requirements.

Utilities and Loading Capacities

Lists required utilities and maximum loading capacities for the unit.

FRONT VIEW

Component Identification

Labels and identifies components shown in the front view diagram.

REAR VIEW

Component Identification

Labels and identifies components shown in the rear view diagram.

OVERALL DIMENSIONS

Dimensional Drawings

Provides visual representations and dimensions of the sterilizer models.

Water Quality Requirements

Built-in Safety Features

Description of Operation Stages

4. CONTROL PANEL

Control Panel Layout

Illustrates the layout of the control panel.

Display Screen Functions

Details the information displayed on the LCD screen during operation.

Keypad Operation Guide

Explains the functions and usage of the control panel keys.

Error Messages and Symbols

Lists and explains error messages and symbols for troubleshooting.

Operational Messages

Describes operational messages and their required user actions.

5. STERILIZATION PROGRAMS

Program Overview and Parameters

Summarizes available sterilization programs and their settings.

Program 1: Unwrapped Instruments

Details parameters and sequence for unwrapped instrument sterilization.

Program 2: Wrapped Instruments

Details parameters and sequence for wrapped instrument sterilization.

Program 3: Unwrapped Pouches

Details parameters and sequence for unwrapped pouch sterilization.

Program 4: Wrapped Pouches

Details parameters and sequence for wrapped pouch sterilization.

Program 5: Unwrapped Delicate Instruments

Details parameters and sequence for unwrapped delicate instrument sterilization.

Program 6: Wrapped Delicate Instruments

Details parameters and sequence for wrapped delicate instrument sterilization.

Program 7: Custom 1

Allows user configuration of parameters for custom sterilization cycles.

Program 8: Custom 2

Allows user configuration of parameters for custom sterilization cycles.

Program 9: Liquid A

Specifies parameters for sterilizing liquids in unsealed bottles.

Program 10: Liquid B

Specifies parameters for sterilizing liquids in sealed bottles.

6. PARAMETERS AND DATA MANAGEMENT

System Navigation Overview

Outlines the system's menu structure for accessing settings and data.

Table of Default Cycle Parameters

Provides a table of default parameters for custom programs.

Accessing the Main Menu

Guides users on how to navigate to the main system menu.

Custom Cycle Parameter Settings

Details how to configure parameters for Custom 1 and Custom 2 programs.

System Parameters Adjustment

Explains how to adjust system-wide settings.

Cycle History Management

Covers viewing and exporting historical cycle data.

12. SERVICE AND MAINTENANCE

Preventive Maintenance Schedule

Details scheduled tasks for maintaining the autoclave's condition.

Daily, Weekly, and Periodic Maintenance

Covers daily, weekly, and periodic cleaning and checks.

Safety Valve Checking Procedure

Procedure for testing the safety valve's functionality.

13. TROUBLESHOOTING GUIDE

Common Malfunctions and Solutions

Provides solutions for common malfunctions and error messages.

14. SPARE PARTS LIST

Available Spare Parts

Lists available spare parts with their catalog numbers.

15. ACCESSORIES

Optional Accessories

Lists optional accessories with their catalog numbers.

Tuttnauer 5075 Specifications

General IconGeneral
TypeAutoclave
Chamber Volume75 liters
Power Supply230V, 50/60Hz
Sterilization Temperature Range121°C to 134°C
Number of Trays3
Chamber MaterialStainless Steel
Weight120 kg
Power3.0 kW
Power Consumption3, 000 watts
Temperature Range105°C to 137°C
Sterilization Time Range5 to 60 minutes
Exterior MaterialSteel
Safety FeaturesOver-temperature protection, pressure relief valve
Cycle TimeVaries depending on load size and sterilization parameters