DESCRIPTION OF TRACTOR CONTROLS
2 - 16
ABNORMAL OPERATION DURING DPF REGENERATION
Item Lamp Buzzer
Coolant temperature over 105˚C
during DPF regeneration
ACK
[DPF]+[EGT] On + Regeneration
button blinking
Release
mode
Regeneration
failure
[DPF]+[EGT] Blinking
Release mode
[DPF]+[EGT] Blinking
Force release
ACK
[DPF]+[EGT]+[Regeneration
button] Blinking