C099-F9P - User Guide
UBX-18055649 - R02 Using the C099-F9P Page 17 of 48
Users can locate the device by examining the Bluetooth connections under the Ports tab in the
Windows device manager for a “Standard Serial over Bluetooth link” - usually the first one in the list.
Use this device for connecting the ZED-F9P to u-center.
Figure 18: Installed Bluetooth SPP port
The ODIN-W2 module communicates with the ZED-F9P via a serial port which is shared with the FTDI
USB/COM port via multiplexors. Once Bluetooth communication is established with the ODIN-W2, a
jumper connection should be made at position “3OE” to connect the serial ports of the ZED-F9P and
ODIN-W2 together. See Figure 19 below.
Figure 19: C099 rover jumper position
For information, Figure 20 below shows the C099-F9P logical connections for serial interfaces with
the “OE3” jumper set as required to connect the ODIN-W2 and ZED-F9P serial ports.
Jumper position “3OE”