5 Rover operation using NTRIP
This section shows how the ZED-F9P is used as a rover using correction information provided over the
internet using NTRIP. This is usually provided by a host from a single reference station or as a Network
RTK Virtual Reference Service (VRS).
Suitable hosts are a PC with internet access and/or an Android cellular phone with mobile data
capability. The host runs an NTRIP client and streams RTCM corrections to the C099-F9P.
5.1 PC hosting via u-center
The u-center application includes an NTRIP client for PC hosting. The u-center user guide [3] provides
help when setting NTRIP service connections. Users can connect via Bluetooth for wireless operation
or directly via a serial COM port. Once the service is active, RTCM corrections are sent over the
connection and data can be logged as usual with u-center.
ā˜ž See the NTRIP section in the u-center User Guide [3].
Enter the required connection settings using the client setting window show below.
Figure 24: u-center NTRIP Client view
Ensure the NTRIP Client connection flag is green for successful connection and RTCM3 data transfer
to the C099-F9P:
Figure 25: u-center NTRIP Client communication indicator