PROBLEM CAUSE SOLUTION
• Only one container is not cooling
(the others are functioning cor-
rectly)
• Electronic circuit board is faulty • Replace the electronic circuit board
• Gas low in the refrigerator circuit • Check for the presence of a gas leak. Once
identified, seal the leak and recharge the
gas (see chapters 9.3. and 9.4.)
• Electrovalve is not opening (coil) • Replace electrovalve coil
• Electrovalve is not opening (body) • Replace electrovalve body
• Only one container is cooling too
much (the others are functioning
correctly)
• The electrovalve is not closing • Replace electrovalve body