Ultimaker S5 Pro Bundle user manual 30
4.8 Uninstalling the Air Manager
In some cases, it may be necessary to uninstall the Air Manager, for example for transportation or maintenance
reasons. Special tools are included in the box to remove the Air Manager from the Ultimaker S5.
It is recommended to uninstall the entire Air Manager, without removing individual modules.
1. Turn o the Ultimaker S5 using the power switch at the back
2. Disconnect the Air Manager cable from the UMB OUT port on the back of the Ultimaker S5 or
the Material Station
3. Take the two removal tools and align them with the leaf springs in the mounting bracket
4. Insert the removal tools behind the leaf springs
5. Push upwards until you hear a click
6. Gently lift the entire Air Manager o the Ultimaker S5
Upon rebooting the Ultimaker S5, a popup will appear on the touchscreen informing that the Air Manager has
been disconnected. Select Yes to conrm the removal of the Air Manager.
4.9 Humidity control
The Material Station has a built-in dehumidier. The dehumidier controls the humidity inside the Material Station.
Silica beads absorb the moisture in the chamber and maintain relative humidity under 40%. The dehumidier will
regenerate the silica beads when they are saturated.
The dehumidier can only regenerate if power is supplied to the Material Station.
If the Material Station has been unplugged for a long period, the dehumidier can take longer than usual to
reach stable conditions.
It is not recommended to store (moisture sensitive) materials in the Material Station if the power
cable is disconnected.