Easier to Read BCD396T/UBCD396T Digital Scanner Manual
To view active IDs in a trunked system press Hold while scanning the system you want to monitor. Scroll to the (noisy) control channel. Active IDs will scroll in the
display. Press Scan to resume.
To view the Trunking Activity Indicators press Vol while scanning a trunked system. You will be able to see the indicators for 10 seconds.
Note: For Motorola systems you must program all system frequencies (control and voice frequencies) for this feature to work.
To lock out a channel or frequency quickly press L/O.
To lock or unlock a group see
Locking/Unlocking Groups.
To lock out a system/search while receiving the system/search, quickly press Func then L/O.
To unlock a conventional channel see
Locking/Unlocking Channels.
To unlock and/or review locked out IDs see
Reviewing Locked out IDs.
To unlock all IDs see
Clear All L/O IDs.
To unlock a system/search press and hold Func-don't let go then scroll to the system/search and press L/O. Releasing Func will return to scanning.
See also
Locking/Unlocking Systems/Searches.
To unlock search frequencies see
Reviewing Locked Out Frequencies.
To start Weather Scan Hold on any channel then press and hold Func then 2(WX). Scroll to 'Weather Scan' and press E/yes.
Programming a Displayed ID (in ID Search Mode)
Contents
To program a displayed ID into an existing group during ID Search, press E/yes.
You will see 'Quick TGID Save?' in the display then press (.)no.
At the 'Select Group' prompt, scroll to the group where you want to store the ID and press E/yes.
After storing the ID, you will be at the '
Edit Channel' menu to complete the settings for the new channel.
If you don't want to edit the channel settings or are done editing the channel, press Scan to return to scanning.
Note: If the ID is already stored in the group, 'TGID Exists' Accept? (Y/N)' appears. Press (.)no to return to searching (or search hold) or E/yes to go
to the '
Edit Channel' menu.
Optimizing P25 Performance
These steps work only when you can clearly receive the system. If you are in a weak-signal area or receive interference, these steps will not work. These steps do not
compensate for weak signals or signals subject to interference.
If you set an incorrect decode threshold level in Step 5, the scanner might stop decoding all digital signals in the system. If this happens, change the setting to a value
between 8 and 12 then repeat these steps.
See also:
P25 audio level decode adjustment at Radio Reference.com.
1. Make sure the system's '
Adjust P25 Level' option is set to 'Auto'.
2. Hold on an active digital channel on the system.
3. While holding down Func, briefly press the scroll control twice. The next to last line on the display now shows the digital error rate and the AUTO decode
threshold start level (0-20). The last line on the display shows the decode threshold levels for the system.
4. Allow the scanner to monitor channel activity for several minutes. The error rate should drop for each transmission and the threshold levels should automatically
adjust to a more optimal setting. Then, once the threshold level settles to a stable setting, make a note of the values. This is the system's optimum decode
threshold.
http://marksscanners.com/396/396.shtml (29 of 51)8/17/2010 10:11:40 PM

Other manuals for Uniden BCD396T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uniden BCD396T and is the answer not in the manual?

Uniden BCD396T Specifications

General IconGeneral
BrandUniden
ModelBCD396T
CategoryRadio
LanguageEnglish

Related product manuals