6. Handset Configuration
7 In the Mode for automatic call after alarm drop-down list, select one of the
following:
Monitor - The loudspeaker is muted and the microphone is on.
Loudspeaker - The loudspeaker is turned on.
Ordinary - The loudspeaker is turned off.
6.9.5 Man-down and No-movement Alarm
NOTE: Applicable to WL3 Plus only.
The following parameters are available in the WinPDM and Device Manager:
Table 4.
Parameter name Description Value {default}
Man-down and No-
movement alarm license
Enables the alarm. No/Yes {No}
Man-down alarm Enables or disables the alarm. Enabled/Disabled
{Disabled}
Man-down detection time Delay before the alarm is activated. 5–255 s {7}
Man-down warning angle The handset tilt from the vertical at
which the alarm is activated.
45, 60 {45}
No-movement alarm Enables or disables the alarm. Enabled/Disabled
{Disabled}
No-movement detection
time
Delay before the alarm is activated. 5–255 s {30}
Warning phase duration Delay before the activated alarm is
sent.
1–255 s {7}
NM-MD extra delay used Enables or disables the possibility of
an extra delay.
Yes/No {No}
NM-MD extra delay time Extra delay before the alarm is sent. 1–20 min {10}
ALS Enables or disables the ramped up
ALS after the alarm has been sent.
NOTE: The ALS is not triggered if the
parameter “Automatic call after
alarm” or “Silent alarm” is active.
Yes/No {No}
Mode for automatic call
after alarm
Off: no automatic call after alarm.
Normal: the call is established as an
ordinary call.
Loudspeaker: the loudspeaker on the
backside of the handset is turned on.
Monitoring: a one-way speech
channel is established, that is, the
called part can only listen to an
conversation.
Off, Normal,
Loudspeaker,
Monitoring {Off}
Turn off NM-MD during call Enables or disables alarms during a
call.
Yes/No {No}

Table of Contents

Other manuals for Unify OpenStage WL3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage WL3 and is the answer not in the manual?

Unify OpenStage WL3 Specifications

General IconGeneral
BrandUnify
ModelOpenStage WL3
CategoryHandsets
LanguageEnglish