c04.fm
A31003-S2000-R102-16-7620, 02/2016
Provisioning Service, Developer’s Guide
217
Nur für den internen Gebrauch Phone Parameters - Administration
Maintenance
4.14 Maintenance
4.14.1 Remote trace
This area is applicable only when using the web interface.
4.14.2 Restart Phone
The regular phone restart, which retains the phone’s settings, is triggered by a special Action,
whose content is Restart. For further information, see Section 3.6.5, "Restart Phone".
4.14.3 Factory reset
This procedure resets all parameters to factory settings and reboots the phone. To start a fac-
tory reset, the Action has to be set to Restart, as with the regular phone restart. Additionally,
the special, fixed password must be provided in the restart-password item, and the
restart-type item must be set to FactoryReset. See the following snippet:
<Item name="restart-password">124816</Item>
<Item name="restart-type">FactoryReset</Item>
4.14.4 HPT interface
WBM Name Item name Type Values Description
Remote Trace
Status
remote-
trace-enable
Bool true/false
Default: false
If enabled, syslog server
will be used for remote
trace.
User Notification remote-
trace-user-
notify
Bool true/false
Default: false
If enabled, the user gets a
notification
Remote Server
IP
remote-
trace-ip
IP Num-
ber
Default: Null Defines IP address of Re-
mote Server
Remote Server
Port
remote-
trace-port
Port
Number
Default: 514 Defines port number of
Remote Server
WBM Name Item name Type Values Description
Disable HPT enable-test-
interface
Bool true/false
Default: true
Used to disable test inter-
face.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage and is the answer not in the manual?

Unify OpenStage Specifications

General IconGeneral
DisplayGraphical LCD
ConnectivityEthernet
Supported ProtocolsSIP
Power over Ethernet802.3af (PoE), depending on the specific model
Supported CodecsG.711, G.729
SpeakerphoneYes
Headset PortYes
USB PortNo
BluetoothNo
Humidity10% to 90% non-condensing

Related product manuals