c06.fm
A31003-S2000-R102-16-7620, 02/2016
Provisioning Service, Developer’s Guide
243
Nur für den internen Gebrauch Phone Parameters - Provisioning
Phone Specific, Hardware Related
device-type Te x t .
Max. 50
characters
OpenStage 15;
OpenStage 20E;
OpenStage 20;
OpenStage 40;
OpenStage 60;
OpenStage 80
Sent to the provisioning service to
identify phone variant. Value is read
only. Displayed in the web page ban-
ner. The value is built up during
phone start up, querying hardware
variant.
OpenScape DPIP35 = OpenStage
20, OpenScape DPIP55 G = Open-
Stage 60
gigabit-
ethernet-
enabled
Boolean true/false Relevant for OpenStage 20/40/60/
80 G / DPIP55G only. Indicates
whether the phone’s network inter-
face is switched to 1Gb/s speed. Val-
ue is read only.
related-
software-type
Text.
Max. 30
characters
Siemens SIP [SIP] Sent to the priovisioning service to
identify phone software type. Value
is read only.
software-type Te x t .
Max. 30
characters
Siemens SIP
[SIP];
Siemens HFA
[HFA]
Sent to the priovisioning service to
identify phone software type. Value
is read only.
part-number Te x t .
Max. 25
characters
Sent to the priovisioning service to
communicate the phone’s part num-
ber. Value is read only.
slk-modules Integer For OpenStage 20E
and OpenStage 20,
the value is always
0.
For OpenStage 15,
the value may be 0
or 1.
For OpenStage 40
to 80, the value may
be 0, 1 or 2.
Number of OpenStage Key
Modules. Sent to the provisioning
service in "ReadAllItems" message
response. Value is read only.
blf-modules Integer For OpenStage SIP
phones, the value is
always 0.
Number of BLF Modules. Sent to the
provisioning service in
"ReadAllItems" message response.
Value is read only.
Item name Type Values Description