Basic Communication Procedures Nur für den internen Gebrauch
A31003-S2000-R102-16-7620 02/2016
40 Provisioning Service, Developer’s Guide
c03.fm
Phone Driven Interactions
3.5.2.4 XML Data Exchange (OpenStage V2R2 onwards)
1. The following example shows XML data sent from a phone with to the provisioning service
after a local configuration change. Note the values of configuration-changed-flag,
configuration-attached-flag, and configuration-attached-number:
<WorkpointMessage xsi:schemaLocation="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns="http://www.siemens.com/DLS">
<Message maxItems="-1"
nonce="BD9438C65D42D90F566E2D03D6083602">
<ReasonForContact>local-changes</ReasonForContact>
<ItemList>
<Item name="device-type">OpenStage 60</Item>
<Item name="related-device-type">OpenStage 60</Item>
<Item name="gigabit-ethernet-enabled">false</Item>
<Item name="software-type">Siemens SIP</Item>
<Item name="related-software-type">Siemens SIP</Item>
<Item name="software-version">V2 R2.30.0</Item>
<Item name="related-software-version">V2 R2.30.0</Item>
<Item name="contact-me-uri">
http://192.168.1.243:8085/contact_dls.html/ContactDLS
</Item>
<Item name="mac-addr">00:01:E3:25:E4:54</Item>
<Item name="configuration-changed-flag">true</Item>
<Item name="configuration-attached-flag">true</Item>
<Item name="configuration-attached-number">2</Item>
<Item name="part-number">S30817-S7403-A108-006</Item>
<Item name="backlight-type">1</Item>
<Item name="sip-mobility-state">0</Item>
<Item name="e164">49897223337</Item>
<Item name="user-pwd">123456</Item>
<Item name="mobility-enabled">false</Item>
<Item name="basic-e164">49897223337</Item>
<Item name="dhcp">false</Item>
<Item name="dls-addr">192.168.1.151</Item>
<Item name="lldp-enabled">false</Item>
<Item name="vlan-method">0</Item>
</ItemList>
</Message>
</WorkpointMessage>
The rest of the interaction is analogical to the startup case, as described in Section 3.5.1, "An
Exemplary Startup Interaction"

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage and is the answer not in the manual?

Unify OpenStage Specifications

General IconGeneral
DisplayGraphical LCD
ConnectivityEthernet
Supported ProtocolsSIP
Power over Ethernet802.3af (PoE), depending on the specific model
Supported CodecsG.711, G.729
SpeakerphoneYes
Headset PortYes
USB PortNo
BluetoothNo
Humidity10% to 90% non-condensing

Related product manuals