c03.fm
A31003-S2000-R102-16-7620, 02/2016
Provisioning Service, Developer’s Guide
67
Nur für den internen Gebrauch Basic Communication Procedures
Provisioning Service Driven Interaction
3.6.10.4 XML Data Exchange: Secure Mode, With PIN
1. As step 1 start-up is described already in Section 3.5.1.2, "XML Data Exchange", only the
subsequent steps are demonstrated here.
2. As the device is configured to Secure Mode with PIN, the provisioning service sends a re-
quest to switch to Secure Mode (bootstrapping) including all items needed packed, en-
crypted and Base64-encoded into the single data item ’secure-mode-data’.
3. <DLSMessage xsi:schemaLocation="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns="http://www.siemens.com/DLS">
<Message nonce="58D4EE11C844865CAF0E9AA11ED2856F">
<Action>WriteItems</Action>
<ItemList>
<Item name="goto-secure-mode">pin</Item>
<Item name="secure-mode-data"><packed-encrypted-
base64encoded-data></Item>
<Item name="max-pin-retries">3</Item>
</ItemList>
</Message>
</DLSMessage>
4. Device responses to default provisioning server port and confirms that the action has been
accepted.
<WorkpointMessage xsi:schemaLocation="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns="http://www.siemens.com/DLS">
<Message fragment="final" maxItems="-1"
nonce="58D4EE11C844865CAF0E9AA11ED2856F">
<ReasonForContact status="accepted" action="WriteItems">
reply-to
</ReasonForContact>
<ItemList/>
</Message>
</WorkpointMessage>
5. The provisioning service sends a CleanUp message.
6. Device needs to display the PIN dialog to the user, to get the PIN for decrypting the secure-
mode-data.
7. The device has decrypted secure-mode-data successfully by using of entered PIN (except
last 3 characters) as password and contacts the provisioning service via Secure Mode port
using the client certificate.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage and is the answer not in the manual?

Unify OpenStage Specifications

General IconGeneral
DisplayGraphical LCD
ConnectivityEthernet
Supported ProtocolsSIP
Power over Ethernet802.3af (PoE), depending on the specific model
Supported CodecsG.711, G.729
SpeakerphoneYes
Headset PortYes
USB PortNo
BluetoothNo
Humidity10% to 90% non-condensing

Related product manuals