EasyManuals Logo

Unify OpenStage User Manual

Unify OpenStage
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Basic Communication Procedures Nur für den internen Gebrauch
A31003-S2000-R102-16-7620 02/2016
76 Provisioning Service, Developer’s Guide
c03.fm
Message Fragmentation
3.7.3.2 XML Data Exchange
For details, see Section 3.6.4, "Modify Phone Settings".
1. The phone sends a response with ’busy’ state.
<WorkpointMessage xsi:schemaLocation="http://www.siemens.com/DLS"
xmlns="http://www.siemens.com/DLS" xmlns:xsi="http://www.w3.org/
2001/XMLSchema-instance">
<Message nonce="957AE6C2E40C0E916B7CD5636480F171" maxItems="-1"
fragment="final">
<ReasonForContact status="busy" action="WriteItems">
reply-to</ReasonForContact>
</Message>
</WorkpointMessage>
2. The provisioning service sends a CleanUp message with ’send-solicited’ item.
<DLSMessage xmlns="http://www.siemens.com/DLS"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.siemens.com/DLS">
<Message nonce="EB2C4CDF45D86E548CCD6F6612B26112">
<Action>CleanUp</Action>
<ItemList>
<Item name="send-solicited">true</Item>
</ItemList>
</Message>
</DLSMessage>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage and is the answer not in the manual?

Unify OpenStage Specifications

General IconGeneral
DisplayGraphical LCD
ConnectivityEthernet
Supported ProtocolsSIP
Power over Ethernet802.3af (PoE), depending on the specific model
Supported CodecsG.711, G.729
SpeakerphoneYes
Headset PortYes
USB PortNo
BluetoothNo
Humidity10% to 90% non-condensing

Related product manuals