36
Weekly or Holiday UV Cleanup Procedure
Perform the “UV Daily Cleanup Procedure” plus the following:
1. Rinse the hose kit with UV Klean by either of the following methods:
2.
Put both ends of the hose into a container with a small amount of UV Klean and energize the pump
by running the iColor coater. Allow the pump to circulate the UV Klean for one to two minutes.
3. Disconnect the hoses from the pump, then pour a small amount of UV Klean into each hose and
slosh back and forth until the UV Klean ows freely in the hoses and then discard the UV Klean
into a cup with a paper towel and dispose of in the trash (no biohazard will exist).
4. Remove the Coating Unit seals from the backing plate kit by the spring clip, manually clean the
seals and the ends of the rollers with UV Klean and reinstall.
CAUTION: Never run the equipment with the seals removed as this will cause damage to the
rollers, which is NOT covered by the roller warranty!
5. Remove the coating drip pan and clean with UV Klean.
6. Remove the doctor blade and clean with UV Klean.
7. While you have the Doctor Blade and the Drip Pan removed, completely clean the Impression roller
with UV Klean. Reinstall drip pan & doctor blade.
8. Dispose of all coating, rags and cleaner as directed per your local regulations.
9.
Pour the contents of the Vac into a disposable container filled with rags or paper towels and
dispose of per your local regulations.
10. Turn the coating unit controls to the “END OF DAY POSITION” to prevent at spots on the rollers.
11. Turn the Main Power disconnect to the OFF position!
Keep It Clean with Komplete UV Klean
It is extremely important to properly clean and maintain your iColor coater. UniNet recommends
UV Klean as a part of your daily UV coating clean-up procedure.
• Water miscible
• Low VOC
• No oily residue
• Meets US & Canadian environmental regulations