9512
LUBRICATION A FUNCTION CHECK
Warning: Turn off slicer and DISCONNECT ELECTRICAL CORD (Figure 1 [10])
before lubricating. Leave protective guard (Fig. 1 [12]) in place.
General lubrication should be performed in accordance with the lubrication instructions below.
During this lubrication sequence, be sure to check for free operation and movement of related
parts as well as for excessive wear and looseness of various parts. Be sure to check all
handles and knobs for tightness.
LUBRICATION INSTRUCTIONS
A = Clean and apply mineral oil weekly. C = 140 WT USDA oil.
Change when changing gears
B = Apply Petro-Gel (4400408) often as
required to maintain light film.
D = Lubricated for life.