diagram:
Eight gases' list is displayed in squares. Square number from left to right corresponds to the
number of gas in the list. It is therefore convenient to have the list of gases from the deepest
to the oxygen in the ascending order. In the example listed on a photo three active OC gases
are numbered 1, 3, and 5.
Color of each square depends on the planned balance for the ascent as a percentage of the
original volume:
Black - not active
White > 50%
Blue > 40%
Green > 30%
Yellow > 20%
Red > 10%
Flashing red square with a cross> 1%
Starting from Firmware 2.7b version AV1 eCCR controller supports the standard tempstick
for Inspiration Vision. Through the same interface C02 sensor can be connected in the future.
->Setup SP
(only in CCR mode) Editing High, Low and Deco Setpoints and Depth of
AutoSwitching.
Next – selection of High or Low Setpoint for editing.
Edit – access to editing mode.
Value range for Low Setpoint: 0.40-0.95, for High Setpoint: 1.00-1.60 with discrete
interval of 0.05. Switching between digits is done with button, changing the value
with +. It will be offered to save results of editing upon navigating through all the
editible fields.