37
If everything is in order, but PO
2
differs from the preset Setpoint by more than 0.2, but
less than 0.4, green indicator is slowly flashing;
If everything is in order, but PO
2
differs from the preset Setpoint by more than 0.4,
green indicator is quickly flashing;
If:
Ascending speed is high (faster than 10 meters/min.);
Decompression ceiling depth is exceeded;
Any Oxygen cell is out of order;
РО
2
is more than 1.6;
РО
2
is less than 0.4;
Low battery charging level;
then green L.E.D. is off, and red L.E.D. indicator starts flashing, and Alarm warning
appears on the screen.
In Surface mode AV1eCCR controller will switch off light alarm (alternate flashing of green
and red HUD L.E.D.s) and sound alarm 20 seconds before switching to Sleep Mode. This
is the warning for the user about approaching controller switching to Sleep Mode. In order
to cancel it, press any button.
7. BUILT-IN COMPASS
AV1 has a built-in magnetic compass with three-axes accelerometer for complete values’
compensation based on angularity of the compass body.
You can use the compass both in the Gauge and in the Recreational modes. Compass
operates both in the Surface and Dive modes. In the Dive mode all the main dive values are
displayed on the screen.
Values of straight and reverse course are displayed on the screen in the Compass mode.