24
FAST - ascending speed higher than 10m/min. System warning, stored in the logbook.
Not bestmix it is recommended to change the gas. There is gas in the list of active gases
which better than the current one. Gases are compared by MOD. The gas / gas mix with
maximum MOD not higher than current depth is considered to be the best mix.
depth, m - current depth, meters
divetime dive time, minutes
NDL non-decompression limit at current depth, minutes. In decompression mode Total
Time to Surface (TTS) is displayed.
stop safety stop depth, meters
time safety stop time, minutes
TTS Total Time to Surface (all required safety stops are taken into account), minutes
ASC (DES) ascending (descending) speed, meters/minute
EAN (tmx) current gas mix
tempC (CNS) ambient temperature, Celsius Degrees (accumulated Oxygen CNS%). These
parameters are displayed in turns with 5 second interval.
Lobat low battery charge indicator
MENU, MIX buttons' current assignment
When coming closer to decompression ceiling a live vertical dynamic decompression
(actual) ceiling graph will be displayed on the basic screen. The alternative screen
shows this value in a digital way in Ceiling field.