10.3 - LOADING THE DEFAULT
PARAMETERS
If necessary, it is possible to restore all parameters to their
standard or default values (see the final summary table).
m PLEASE NOTE: This procedure results in the loss of all
customised parameters.
1. Press and hold the OK key until the display shows -dEF
2. Release the OK key: the display shows ESC (only press the
OK key if it is desired to exit this menu)
3. Press the i key: the display shows dEF
4. Press the OK key: the display shows no
5. Press the i key: the display shows YES
6. Press the OK key: all parameters are overwritten with their
default values (see Chapter 12), the control units exits
programming mode and the display shows the control panel.
dEF.
ESC
-dEF
Si
no
SEnS SEnS
ESC
-SEn
10.2 - AUTOMATIC SENSITIVITY
ADJUSTMENT
1. Press and hold the OK button until the display shows -SEn
2. Release the OK button: the display shows ESC
(press OK only if you want to exit this menu)
3. Press the i key: the display shows SEnS
4. Press the OK button to start the procedure: the message
SEnS flashes on the display and the gate performs a full
closing cycle until reaching the end of stroke (complete
opening phase and complete closing phase).
5. When the procedure is finished, the display shows the control
panel
m ATTENTION: if the control unit receives a START
command during the automatic learning procedure, the
procedure is aborted and the control unit stores the partial
data determined.