If you keep the package in storage for more than 2 months, keep it in controlled conditions.
Make sure that the temperature variation is small and that the humidity is less than 50%.
3.5 REMOVING THE PACKAGING AND LIFTING THE AC DRIVE
3.5.1 WEIGHT OF THE AC DRIVE
The weights of AC drives of different enclosure sizes are very different. It can be necessary
for you to use a lifting device to move the drive from its package.
Table 4: The default weight of the enclosed drive and some options
Enclosure size The enclosed drive,
IP21/IP54, without
options [kg]
Common mode filter
+ du/dt filter [kg]
The sine filter [kg] Any of the 3 cabling
from top options [kg]
MR8 200 30 270 65
MR9 270 40 270 65
MR10 420 40 350 80
MR12 825 80 700 95
3.5.2 LIFTING THE AC DRIVE
The AC drive is delivered horizontally or vertically on a wooden pallet. Most enclosure sizes
of the AC drive include additional cabinet sections when you order any of the 3 cabling from
top options (+CHIT, +CHOT, or +CHCT), the input contactor (+CICO), or the sine filter (+COSI).
The products are delivered with all the cabinets attached together, except for the MR12 if you
order it with the +COSI option and/or the +CICO option.
MOVING THE ENCLOSED DRIVE
1 Do not remove the package material before you
install the AC drive.
2 Put the drive onto a level base.
3 Move the drive in the vertical position.
VACON · 16 RECEIVING THE DELIVERY