4.2.4 WALL MOUNTING OF FR9
D1
D2
Ø
D3
W1
W4
W2
H4 H3
W3
H5
H2
H1
H6
E1Ø
W5W5
B-B+/R+R-
Fig. 7: Dimensions of the NXS and NXP AC drive, FR9
Table 8: Dimensions in mm (in inch) of the NXS and NXP AC drive, FR9, part 1
Drive type W1 W2 W3 W4 W5 D1 D2 D3
0261 2-0300 2
0261 5-0300 5
0125 6-0208 6
480
(18.9)
400
(15.75)
165
(15.74)
9
(0.35)
54
(2.13)
362
(14.25)
340
(13.39)
285
(11.22)
Table 9: Dimensions in mm (in inch) of the NXS and NXP AC drive, FR9, part 2
Drive type H1 H2 H3 H4 H5 H6 Ø E1Ø
0261 2-0300 2
0261 5-0300 5
0125 6-0208 6
1150*
(45.28*)
1120
(44.09)
721
(28.39)
205
(8.07)
16
(0.63)
188
(7.40)
21
(0.83)
59
(2.32)
* = Brake resistor terminal box (H6) not included. For FR8 and FR9 when Brake chopper or
Additional DC connection is selected in type designation code, the total height of the AC drive
is increased by 203 mm (7.99 inch).