4 Defaulting the controller and configuring the IP address
This section describes the following.
4.1 Defaulting the Controller and IP Address Configuration 17
4.1.1 Factory default the Controller (DIP switch 2) 17
4.1.2 DHCP/static IP addressing (DIP switch 1) 18
4.1.3 Defaulting the static IP address 18
4.1.4 Changing static IP address on the ACTpro Controller 18
4.1 Defaulting the Controller and IP Address Configuration
The ACTpro-1500 has two DIP switches.
l DIP switch 1: DHCP
Enables DHCP or Static IP address mode.
l DIP switch 2: DEFAULT
Defaults the controller or the Static IP address.
4.1.1 Factory default the Controller (DIP switch 2)
The ACTpro Controller may be defaulted to factory settings. This will completely erase the controller
memory. All information including card details will be erased and the static IP address will be reset to
192.168.1.60.
To default the ACTpro Controller:
1. Power down the ACTpro Controller.
2. Set the DEFAULT DIP switch 2 to ON.
3. Hold down the Tamper spring.
4. Apply power to the ACTpro Controller.
5. Wait approximately 5 seconds, until the controller confirms default completed by sounding the
buzzer.
6. Release the Tamper.
7. Power down the ACTpro Controller.
8. Set the DEFAULT DIP switch to OFF.
9. Re-apply power.