6 Status Indicators
6.1 ACTpro-1500
Status indicators appear on the front of the ACTpro-1500 Door Controller.
The meaning of each indicator is described below.
(A) Power / System Running
This indicates that the ACTpro controller has power.
(B) Communications
Constant illumination indicates that all enabled door stations are online.
Flashing indicates that one or more door stations are offline.
(C) Fault
Illuminates to indicate a fault on the system.
Possible causes are:
l Tamper open: ACTpro controller housing is not closed.
l Break Glass: ACTpro controllers provide a method to monitor an Emergency break glass switch via the
B/GL input. The Fault LED illuminates if the Emergency break glass switch is activated.
l ACFault: ACTpro-1500 controller accept an AC present signal from a PSU . This is wired into the AC
MON input on the PCB. When the PSU has no AC supply the fault is active.
l Door Station offline: When one or more enabled door stations are not communicating with the ACTpro
controller the Fault LED illuminates and the appropriate network green LED on the PCB flashes.
l Low Supply Voltage: When voltage to the +12V/24V terminal is less than +9V.
l Fuse Blown: The +12V output on the READER terminals is current limited to provide short circuit
protection. The Fault LED illuminates if too much current is drawn from this connection.
© Vanderbilt 2020 23 A-100667