1 Overview
This guide describes the installation of the ACTpro-1500 controller.
The ACTpro-1500 Controller is a single door IP controller that requires an external 12V or 24V power
supply.
Capabilities
Number of Doors 1
Number of Users 60,000 (4 credentials per user)
User Groups 2000
Time Zones 250
Door Groups 1000
Log Events 20,000
Browser Compatibility Chrome, Firefox Version 8.0 or later, Microsoft Internet Explorer 8 or later
1.1 Ordering information
Controllers Product Code Description
ACTpro-1500 V54502-C111-A100 Single door IP controller expandable to 32 doors with ACTpro door
stations.
ACTpro-1520 V54502-C110-A100 Controller with integrated 12V 2A DC power supply.
ACTpro-1500PoE V54502-C112-A100 Single door IP controller with PoE + PSU.
ACTpro-100 V54502-C120-A100 Door station, single door
ACTpro-120 V54502-C122-A100 Door station with integrated 12V 2A DC power supply, single door.
ACTpro-IOM V54506-B100-A100 IO module (8 inputs and 8 outputs)
1.2 Technical specification
ACTpro-1500
Voltage Range (Controller) 1124V DC
Current Consumption (Controller) 350mA (Max)
Controller Dimensions (H x W x D mm) 165 x 236 x 55
Controller Weight (kg) 0.4
Operating Temperature -10 to +55° C
Operating Environment Surface mounting
Internal use only
© Vanderbilt 2020 4 A-100667
18.06.2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt ACTpro-100 and is the answer not in the manual?

Vanderbilt ACTpro-100 Specifications

General IconGeneral
BrandVanderbilt
ModelACTpro-100
CategoryController
LanguageEnglish

Related product manuals