EasyManua.ls Logo

Vanderbilt ACTpro-100 - 5.2 Deadbolt Wiring Diagrams

Vanderbilt ACTpro-100
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACTpro 1500
connection
ACTpro 100
connection
Connected to
ASSA ABLOY
Hi-O door control unit
(e.g. DAC-564)
ASSA ABLOY
monitored deadbolt
lock
(e.g. EL573)
AUX RELAY
Note: This relay
will fire on an
access/exit granted
event.
AUX RELAY
Note: This relay
will fire on an
access/exit
granted event.
BUTTON IN
(To trigger the deadbolt.)
C - Deadbolt lock
(0V applied retracts
deadbolt.)
MAIN RELAY MAIN RELAY Door strike
(To control the latch.)
Door strike
(To control the latch.)
OP2
OP3
OP2
OP3
(Optional) Connect to an external device that should
be triggered if there is a deadbolt problem such as
door ajar, door forced or deadbolt unsecured.
Wiring diagrams for connecting an ASSA ABLOY monitored deadbolt lock and an ASSA ABLOY Hi-
O control unit to an ACTpro-1500 controller are shown below for illustrative purposes. Other lock
types are supported similarly. Refer to the manufacturer documentation for hardware and wiring
specifications to establish the appropriate connections.
ASSA ABLOY monitored deadbolt lock wiring to ACTpro-1500
A Alarm (optional) D Monitor deadbolt position
B Door contact (optional) E Trigger the deadbolt
C Door strike (controls latch)
ACTpro-1500 Door Controller Installation and Operating Instructions Configuring a lock with a deadbolt
© Vanderbilt 2020 21 A-100667
18.06.2020