OPERATING INSTRUCTIONS
for the
WRM-10P
WRM-40
TRANSFORMER-WINDING
RESISTANCE METER
Vanguard Instruments Company
1710 Grevillea Court
Ontario, California 91761
TEL: (909) 923-9390 Oct 2002
FAX: (909) 923-9391 Rev 1
Question and Answer IconNeed help?

Do you have a question about the Vanguard Instruments WRM-10P and is the answer not in the manual?

Vanguard Instruments WRM-10P Specifications

General IconGeneral
ModelWRM-10P
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 70°C
Accuracy±0.1% of reading
InterfaceUSB
Measurement Range0.1Ω to 2000Ω
Resolution0.1 μΩ
DisplayLCD
Test Current1mA
Weight12 lbs (5.4 kg)

Summary

1.0 INTRODUCTION

1.1 General Description

Describes the WRM-10P/40 as microprocessor-controlled winding resistance meters for various applications.

1.2 Functional Description

Explains the operation of WRM-10P/40 based on Ohm's law and its current source capabilities.

1.3 Furnished Accessories

Lists the standard accessories included with the WRM-10P/40 unit.

2.0 WRM-10P/40 SPECIFICATIONS

3.0 CONTROLS AND INDICATORS

4.0 PRETEST SETUP

4.1 Operating Voltages

Explains how to select operating voltages (90-130Vac or 200-240Vac) using terminal block jumpers.

4.2 WRM-10P/40 LCD Contrast Control

Provides instructions on how to adjust the brightness of the device's LCD screen.

4.3 WRM-10P/40 Printer Paper Control

Details the procedure for advancing or retracting the thermal printer paper.

5.0 WRM-10P/40 PRINTER PAPER

6.0 OPERATING PROCEDURES

6.1 WRM-10P/40 Cable Connection

Shows typical connection diagrams illustrating how to connect the WRM-10P/40 to a transformer for testing.

6.2 General Procedures

Outlines initial operational steps such as grounding the unit, connecting power, and inserting test cables.

6.3 Step-by-Step Procedures at Start-Up Menu

Details the sequence of operations for performing tests, starting from the device's main Start-Up menu.

6.3.1 START-UP Menu

6.3.2 Test Transformer Procedure

6.4 SETUP MENU

6.4.1 Transformer Data Entries

Guides the user through entering essential transformer identification data such as company, station, and model numbers.

6.4.2 Restore a Test Record

Details the process for retrieving previously saved test records from the device's Flash EEPROM.

6.4.3 Review a Test Record

Explains how to view saved test records either on the LCD screen or by printing them.

6.4.4 Printing Test-Record Directory

Describes the procedure for printing a list of all test records currently stored in the device's memory.

6.4.5 Erase a Test Record

Provides instructions for deleting either a single specified test record or all saved records.

6.4.6 Enabling Computer Interface

Explains how to connect the WRM-10P/40 to a PC via RS-232C for retrieving test data.

6.4.7 Setting Date and Time

Covers the procedure for setting the device's internal clock, including date and time adjustments.

6.4.8 Voltage Regulator Test

Details how to perform a specific test on the regulating tap switch for continuity and detect breaks.