1.6  Technical data 
1.6.1  Control and actuating unit 
+24 VDC (±10%) @ 0.5 V pk-pk max. 
Sensor power supply output 
2)
 
Sensor input 
  Signal input voltage / Input resistance 
  ADC resolution 
  Sampling time 
 
 
0-10 VDC / Ri>100 kΩ (linear to 
pressure) 
0.23 mV 
10 ms 
Digital outputs 
3) 
  Input voltage 
  Input current 
  Breaking capacity 
 
70 VDC or 70 V peak max. 
0.5 ADC or 0.5 A peak max. 
10 W max. 
Analog outputs 
3) 
(optional) 
PFO
4)
 battery pack (optional) 
  Charging time 
  Durability 
 
 
2 minutes max. 
up to 10 years @ 25°C ambient 
refer to «Durability of power fail battery» for details 
0 °C to +50 °C max. (<35 °C recommended) 
Pressure control accuracy 
5 mV or 0.1% of setpoint, whichever is greater 
Position resolution / position control capability 
Closing time throttling only 
Opening time throttling only 
Closing time throttling & isolation 
Opening time throttling & isolation 
 
1)
 Internal overcurrent protection by a PTC device. 
2)
 Refer to chapter «Sensor supply concepts» for details. 
3)
 Refer to chapter «Schematics» for details. 
4)
 PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details.