Volta Air Technology Owner’s Manual
Van Refrigeration & Freezer Unit
43
CONFIDENTIAL
Maintenance
Refrigerant volume (check with level glass)
1. If volume is lower than the previous check, investigate leak by looking for oil
Condenser
Remove all debris inside fan or in condenser
1. Disconnect main battery cable to avoid shock
2. Remove cover
3. Clean fan(s) and condenser with compressed air from a safe distance to avoid
breaking fins
4. Check if any plugs or connections are loose
5. Look at wiring see if any sign of excessive heat or dirt, clean if necessary
6. Put main cover back on and reconnect main battery
Evaporator
Remove all debris inside fan or in condenser
1. Disconnect main battery cable to avoid shock
2. Remove cover
3. Clean fan(s) and evaporator with compressed air from a safe distance to avoid
breaking fins
NOTICE
WARNING!
1
Never clean the refrigeration unit when connected to the battery or power supply
Use non-flammable solvents for cleaning
Never touch or power-wash the pipes or components inside the unit, use
compressed air from a safe distance away to remove debris
Always wear the proper PPE for eye and hand protection