11,
TECHNICIAN PROGRAMMING.
The technician menu is made up of the following submenus:
• Language
Settable data.
• Name
Not changeable.
• Service Tel.
Settable va lue.
• Dose programming
Do not change the value, but leave the factory setting “ENABLED”.
• Continuous button
Do not change the value, but leave the factory setting “ENABLED”.
• Mixed water
Do not change the value, but leave the factory setting “NO”.
• Preinfusion
Do not change the value, but leave the factory setting “DISABLED”.
Do not change any of the preinfusion values, but leave the factory settings.
• Sensitivity
Do not change the value, but leave the factory setting “MEDIUM”.
• Maintenance cycles
Do not change the value, but leave the factory setting “0”.
• Temperature
Settable va lue.
• No. of units
Do not change the value, but leave the factory setting “2 for two units, 3 for three units, 4 for four units”.
• Unit 1 temp.
Settable va lue.
• Unit 2 temp.
Settable va lue.
• kP - kI - kD
Do not change the values, but leave the factory settings “kP=0.3 - kI=0.00 - kD=0.2”.
Manuale_Replica2B Elettronica_Rev0_5lingue_03-2016.indd 31 19/04/16 17:28