PLRF25C-1.2en Distance gate
29
Distance gate
In certain cases, it may be
useful to limit the closest
distance the device will
measure. Click the button
three times in rapid
succession.
DIS-GATE appears briefly
followed by the current
setting.
Click the button to scroll
through the available
values.
D GATED is displayed
when a distance within
the set distance gate is
measured.
To store the desired setting,
press and hold down the
button for >2 seconds. The
setting is not changed if
CANCEL is displayed.
3x
DIS-GATEDIS-GATE
SET OFFSET OFF
OFF
200m
300m
400m
SET OFFSET OFF
200ç 200ç
300ç 300ç
400ç 400ç
SET 300çSET 300ç
-STORED--STORED-
300ç300ç
-STORED--STORED-
>2s