Solar Pump Controller Manual
25
E-53
A
ct voltage for
energy break
110150%
150%
135H
E-54
A
ct ratio for
energy break
0100%
25%
136H
E-55
Bus
under-voltage
protection value
6090%
70%
137H
E-56
Motor rated
voltage
1001140V
138H
E-57
Motor rated
current
0.11000A
139H
E-58
Motor rated
frequency
25.00400.0Hz 50.00
13AH
E-59
Motor rated
speed
065000 1460
13BH
E-60
Output voltage
ratio for solar
pump control
50100%
100
13CH
E-61
G/P model set
0:G model
1:P model
0
13DH
E-62
Stable time for
speed track
0.2010.00s
0.60
13EH
E-63
Parameter
change
protection
0: Can change all parameter
1:Can only change parameter set
by keyboard no
2:Can not change all
0
13FH
E-64
Parameter
initialization
0:No act
1:Recover factory setting
2:Clear fault record
0
140H
E-65
Factory
password
09999
0
141H
E-66
Information
check
0:No act
1:Check state monitor
2:Check fault information
0
142H
E-67
Restrain disturb
LED “0”digit: restrain disturb of
OV
0:Invalid
1:Valid
LED “00”digit: restrain disturb of
SC
0:Invalid
1:Valid
LED “000”digit: restrain disturb of
OC
0:Invalid
1:Valid
LED “0”digit: reserved
0001
143H