EasyManua.ls Logo

Veichi SI10 - Solar Pump Controller Parameters Explain

Veichi SI10
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solar Pump Controller Manual
37
Solar pump controller parameters explain:
Note: [H-32~H-65] is valid only if solar pump control mode ( E-02 set to 10)
H-32
Lowest run frequency Range: 0.00Hz 300.00Hz
Factory setting20.00
H-33
Lowest run frequency
duration
Range: 0.1S 6500.0S Factory setting10.0
Controller output frequency is lower than[H-32]value after[H-33]time, controller enters stop and wait
state
H-34
Stop and wait time Range:0.1S 6500.0S
Factory setting30.0
After controller enters stop and wait state, it can only stop wait state after certain time. Wait time is
rerated to[H-61]repeat times in dormancy and[H-33].
Stop and wait state or dormancy wait time:[H-61]times<=3 times, the wait time is H-34 set time*1;
Times<=6, the wait time is H-34 set time *4; Times<=9, the wait time is H-34 set time *8; Times<=12,
the wait time is H-34 set time *16; Times>=13, the wait time is H-60 set time (factory set as 15mins);
H-61 can check the times. Dormancy time can be adjusted by H-34 setting value.
H-35
Automatic dormancy voltage Range01000V Factory setting:※
H-36
Renew voltage in dormancy Range01000V Factory setting:※
H-37
Max MPPT voltage setting Range01000V Factory setting:※
H-38
Min MPPT voltage setting Range01000V Factory setting:※
Bus voltage is lower than H-35(Automatic dormancy voltage), solar pump controller enters in
dormancy. Bus voltage is higher than H-36(Renew voltage in dormancy), solar pump controller
stops dormancy and start again after certain time. Under running state, bus voltage is higher than
H-37, output frequency increases as ratio. Until bus voltage lower than H-37, it starts MPPT search
function. Output frequency reduces quickly while bus voltage is lower than H-38. Output
frequency×H-59 result is the output frequency of next cycle.
H-37 (Max MPPT voltage setting) and H-38(Min MPPT voltage setting) should be set reasonablly to
face strong sunshine change, such as cloudy weather.
H-39 MPPT voltage search interval Range0.06500.0s Factory setting0.0
H-40
MPPT voltage step length
compensation
Range02.00Hz Factory setting1.00
H-41 MPPT sample cycle Range0.016500.00s
Factory setting0.05
H-42 Search repeat times Range0100 Factory setting2
H-43
DC current detect measuring
range
Range01000.0A Factory setting0.0A