Technical Specification
Solar
pump
controller
power(KW)
Pump motor Max
solar
power
input
(KW)
Max DC
input
voltage V
Recommend
MPPT
voltage (V)
Rated
output
current
(A)
Output
frequenc
y(Hz)
Rated
motor
(KW)
Rated
voltage
(V)
0.75/1.5 0.75/1.5
100-330
1.95 350 100~350 10A 0-60
0.75 0.75 220 1.0 400 220~400 4A 0-60
1.5 1.5 220 1.95 400 220~400 7A 0-60
2.2 2.2 220 2.86 400 220~400 10A 0-60
3.7 3.7 220 4.81 400 220~400 17A 0-60
1.5 1.5 380 2.2 780 480560 3.7 0-60
2.2 2.2 380 3.3 780 480560 5.0 0-60
3.7 3.7 380 5 780 480560 8.5 0-60
5.5 5.5 380 8 780 480560 13 0-60
7.5 7.5* 380 10 780 480560 17 0-60
11 11* 380 14.3 780 480560 25 0-60
15 15 380 19.5 780 480560 32 0-60
18.5 18.5 380 23.4 780 480560 38 0-60
22 22 380 28.6 780 480560 45 0-60
30 30 380 39 780 480560 60 0-60
37 37 380 48.1 780 480560 75 0-60
45 45 380 58.5 780 480560 90 0-60
55 55 380 71.5 780 480560 110 0-60
75 75 380 97.5 780 480560 150 0-60
93 93 380 120.9 780 480560 180 0-60
110 110 380 143 780 480560 210 0-60
132 132 380 171.6 780 480560 250 0-60
160 160 380 208 780 480560 310 0-60
185 185 380 240.5 780 480560 340 0-60
200 200 380 260 780 480560 380 0-60
1.4 Cautions in disposal
When you dispose frequency inverter, please pay attention to:
1. Electrolytic capacitor: the electrolytic capacitor of main circuit or the printing plate may explode
when they are burned.
2. Plastic: plastic incineration may generate toxic gases.
3. Dispose method: please dispose as industrial waste.