top trays.
2) Are all reflectors on latch and hinge side
trays installed.
Install any missing reflectors.
Missing
Coordinates
During the 'Discovery
Operation', a tray
reflector was not
found.
Check power on the FLO device. The Green
Light should be on.
Test FLO with a corner-cube reflector piece.
When the reflector is in front of the FLO, the
second light should change from 'Off' to
Orange.
Check all the trays are properly seated on the
base metal.
If the Green Light is off, check the plug on the PDC.
If the Orange Light does not turn on/ off, replace the
FLO assembly.
If the FLO does turn on/ off replace the PDC board.
Reseat tray firmly in shelf
Missing Tray A tray is missing on
the top or bottom
shelf.
There should be a reflector on each tray on top
and bottom shelves.
Install any missing reflectors.
Check all tray positions. Make sure each tray
has a corner-cube reflector in the center tray
pocket.
Replace any missing tray reflectors. Run Discovery 2.