Test Mode: - Test Motors - Vending - perform
Test Vends.
Check the sensors in Test Mode - Check
Sensors.
POWER DOWN.
Replace any malfunctioning motors or sensors.
POWER ON.
If the problem persists, change the PDC and the Main
Control Board.
Setup Flash Write
Failed
Changes to the
configuration could
not be stored in the
PDC’s FLASH chip.
POWER DOWN, wait 5 seconds, then POWER
ON.
1) If issue persists, the FLASH chip has failed.2) Save
all relevant information for PDC's Configuration. 3)
Remove the FLASH chip using a 'chip extractor tool'
and gently prying away from the housing.4) Replace
defective FLASH chip with the new one, pressing
gently into position. 5) If the FLASH chip change does
not work (after several attempts), replace the
Hand.? 6) If it is a 3 Tray GFV, it will need to be re-
programmed in 'Calibration: Set # of Trays'. The
embedded default is 4 trays.
Failed
Conformation
Discovery 1 scanned
the latch side of the
GFV and the trays
discovered do not
match those stored in
FLASH.
tray configuration
changed.
Vendor will automatically perform a Discovery
2.
If no changes were made to the trays/shelves in GFV,
it may indicate a missing reflector.
Inappropriate
Command
Test/Config Mode
command received
while the VMC is not
in Test/Config Mode.
Eg. Test Motors
command received
while the machine is
vending.
PDC will ignore the inappropriate command.