Command Out of
Sequence
The MDB command
requested is
inappropriate for the
current state of the
PDC.Eg. If the "Vend
Drop" command was
received when the
hand was not at the
hopper to drop a
product during either
a Vend, Startup, or
Recovery.
PDC will ignore the command. It should recover by itself. If it is a frequent
occurrencechange the 'Hand'.
Command in
Progress
Test/Config Mode
command received
while the VMC is in
the process of
executing a
Test/Config
command.
PDC will automatically ignore the command.
Command Data
Out of Range
Test/Config Mode
received an invalid
comand.
VMC will retry sending the command to PDC
It should recover by itself. If it is a frequent occurrence
change the 'Hand'.
Command
Denied Safely
A command was
rejected because it is
unsafe.
PDC will automatically ignore the command. Call Tech Services at: 1-800-344-7216
Shelf Invalid Test/Config
commands that have
a shelf number as a
parameter, can return
this error for a shelf
number, while in
range, which
identifies a shelf that
was not found during
discovery.
Performing Calibrations / Set Z corrections
without running discovery will cause this error.
Service Mode: Calibration Discovery -
Run Discovery 2
before making any Changes.