Cycles Per Hour (Setup Step 14)
TheCyclesPerHoursettingmaylimitthe
numberoftimesperhouryourHVACunit
mayenergize.Forexample,atasetting
of6cyclesperhourtheHVACunitwill
onlybeallowedtoenergizeonceevery
10minutes.TheCyclesPerHourlimit
maybeoverriddenandresetbypressing
theWARMERorCOOLERbuttonsonthe
thermostat.SettingsareNoLimit,2,3,4,5,
or 6 cycles per hour.
Compressor Minimum
Off Minutes (Setup Step 15)
This feature allows the user to set a
minimum off time for the compressor.
Settingsare0to5mins.
Minimum Heat/Cool Setpoint
Difference (Setup Step 16)
This feature allows the user to set the
minimumgapbetweenHeatandCool
setpointsinAUTOmode.Selectfrom
0to6degrees.
Installer Setup