Fan Off Delay in Seconds (setup step 21)
This feature allows the user to increase the
coolingorelectricstripheatingefciencyofthe
system.Thethermostatmaybeprogrammedto
continuerunningthefanafteracallforcooling
orelectricstripheatinghasbeensatised.This
delay can be set for 0, 30, 60, 90, or 120 seconds.
If set to 0, the fan will not run after a call for
coolingorelectricstripheatinghas
been satisfied.
Fahrenheit or Celsius (setup step 22)
This feature allows the thermostat to display
temperatureinFahrenheitorCelsius.
Comfort Recovery (setup step 23)
WithComfortRecoveryon,thethermostatwillattempttoreachthe
Morningsetpointtemperatureattheexacttimeprogrammedinto
thethermostat.ComfortRecovery,onlyworkswhenthethermostat
enterstheMorningperiodfromtheNightPeriod.Forexample,ifthe
NightPeriodissetfor11pmat65°Fheatingand85°Fcooling,andthe
MorningPeriodissetfor6amat72°Fheatingand75°Fcooling,the
thermostatwillturnthesystemonbefore6aminanefforttobringthe
temperaturetoitscorrectsettingatexactly6am.Thethermostatlearns
fromexperience,howearlytoturnon,sopleaseallow4-8daysaftera
programchangeorafterinitialinstallationtogive
ComfortRecoverytimetoadjust.Ifusedwitha
heat pump, electric strip heat will be disabled
whileComfortRecoveryisactive.
Installer Setup
23