Fan Off Delay in Seconds (setup step 21)
This feature allows the user to increase the
coolingorelectricstripheatingefciencyofthe
system.Thethermostatmaybeprogrammedto
continuerunningthefanafteracallforcooling
orelectricstripheatinghasbeensatised.This
delay can be set for 0, 30, 60, 90, or 120 seconds.
If set to 0, the fan will not run after a call for
coolingorelectricstripheatinghas
been satisfied.
Fahrenheit or Celsius (setup step 22)
This feature allows the thermostat to display
temperatureinFahrenheitorCelsius.
Comfort Recovery (setup step 23)
WithComfortRecoveryon,thethermostatwillattempttoreachthe
Morningsetpointtemperatureattheexacttimeprogrammedinto
thethermostat.ComfortRecovery,onlyworkswhenthethermostat
enterstheMorningperiodfromtheNightPeriod.Forexample,ifthe
NightPeriodissetfor11pmat65°Fheatingand85°Fcooling,andthe
MorningPeriodissetfor6amat72°Fheatingand75°Fcooling,the
thermostatwillturnthesystemonbefore6aminanefforttobringthe
temperaturetoitscorrectsettingatexactly6am.Thethermostatlearns
fromexperience,howearlytoturnon,sopleaseallow4-8daysaftera
programchangeorafterinitialinstallationtogive
ComfortRecoverytimetoadjust.Ifusedwitha
heat pump, electric strip heat will be disabled
whileComfortRecoveryisactive.
Installer Setup
23